Heating rod for heating the melting filament, 60W
Temperature sensor for detecting the temperature of the heating block, type NTC 100K
Heater extruder not heating at expected rate
The after-sales service team analyzed and determined that the fault was caused by the heating rod
shut down:ADC out of range
shut down:Extrude below minimum temp
The after-sales service team analyzed and determined that the fault was caused by the temperature sensor
H1.5 hexagonal wrench
H2.0 hexagonal wrench
New temperature sensor or heating rod
Before starting any disassembly and assembly, make sure the machine is powered off and all wire sequence terminals on the effector are unplugged.
You need to remove the toothed wire guard first, you can refer to the toothed wire guard video.
Be careful not to forget these two small screws during both disassembly and assembly.