Used to measure and adjust the distance between the hot bed and the print nozzle to ensure the adhesion and print quality of the printed substrate.
The hot bed pressure sensor fails or does not work
Frequent miscalibration of the pressure sensor determined by the flsun after-sales service team.
H1.5 Allen wrench
H2.0 Allen wrench
H2.5 Allen wrench
New hot bed pressure sensor
Note: Before starting any disassembly and assembly, make sure the machine is powered off.
¶ 1. Use the H2.0 Allen wrench to remove the screws that fix the outer cover on the right side and remove the side panel.
¶ 3. Remove the camera, disconnect the LED connection wire, and move the LED wire away to avoid damaging the wiring harness.
¶ 4. From the side door, gently remove the cover. Note that the main door must be closed, otherwise it will block the cover and cannot be removed.
¶ 5. Use an H2.0 Allen wrench to remove the 6 screws that secure the lower housing and the lower case.
¶ 10. Unplug the terminal corresponding to the sensor and remove the sensor and support.
¶ 11. Use pliers and an H2.5 Allen wrench to remove the pressure sensor from the support.
Note: When installing the cover, align the empty space.
https://youtu.be/EkdiCIsP_UQ